Power Controller - REVO-C 1PH-480V-30A
REVO-C (RC1030-4) single phase (1PH) solid state relay / thyristor (SCR) power controller, suitable for loads up to 480Vac and a maximum current rating of 30 amps.
A wealth of options include Wi-Fi, Datalogging, Energy Totalising, Current Limit and Heater Break Alarm as well as industry standard communications options such as Modbus, Profibus & Profinet, enabling equipment and factory automation.


CD Automation's new REVO-C thyristor (SCR) power controller range is flexible and powerful, and available with a variety of options allowing one platform to be re-used across a wide range of applications saving time and money. REVO-C single phase models include sizes from 35 to 800 amps, with 3 voltage ranges up to 480Vac, 600Vac and 690Vac.
A wealth of options include Wi-Fi, Datalogging, Energy Totalising, Current Limit and Heater Break Alarm as well as industry standard communications options such as Modbus, Profibus & Profinet, enabling equipment and factory automation.
Controller firing modes include zero cross, burst firing, single cycle and half cycle, delayed triggering and phase angle. These smart algorithms enable the product to easily control a wide base of heater loads including Nichrome®, moly, silicon carbide, tungsten quartz and infrared lamps and transformer-coupled loads. REVO-C 1PH offers a comprehensive list of modular options that deliver space and labour savings including controlled legs (1, 2 or 3), semiconductor fusing, load current measurement and user interface.
REVO-C equals REVO-Connect with its unique mobile phone app giving you access to the power controller from outside the cabinet. Extremely helpful if you have questions with your process control and want to view key parameter values with the process live and the control cabinet closed.
Product Name | Power Controller - REVO-C 1PH-480V-30A |
---|---|
Software |
Thyristor Configurator Software. Version V5.7.0.2. 23.7MB download file size. |
Firing Range | Zero Cross (ZC), Half Cycle (HC), Single Cycle (SC), Burst Firing (BF), Delayed Triggering (DT), Phase Angle (PA), Soft Start (SS) |
Input Signal | DC logic (SSR), 0-20mA, 4-20mA, 0-10Vdc, 10K Pot |
Communication | Modbus RTU as standard, Profibus DP and Profinet as option. |
Feedback Type | Voltage (V), Current (I) and Power (VxI), or Voltage Square (V2) and Current Square (I2) with additional transfer to VxI |
Option | Current Limit, Heater Break Alarm, WiFi, Datalogging, Energy Totalizer. |
Ideal For | All load types |
Approvals | cUL and CE + EMC approved |
Altitude | Over 1000m of altitude reduce the nominal current of 2% for each 100m. |
Auxiliary Voltage Supply | 90:130Vac 8VA Max |
Controlled Phases | 1 |
Heater Break Alarm | To diagnose partial or total load failure with automatic setup, relay alarm output and LED indication, available as an option |
Humidity | From 5 to 95% but without condensation or surface ice |
Mounting | DIN-Rail or Screw mounting |
Load Type | Single Phase (Phase to Phase or Phase to Neutral) |
Panel Sealing | IP20 |
Storage Temperature | -25 °C to 50 °C Max |
Voltage Power Supply | From 24V to 480Vac (Standard) or 600V & 690V as option on specific models |
Voltage Frequency | Automatically from 47 to 70 Hz |