Solid State Relay - REVO-S 3PH 600V-35A
Designed to replace contactors, REVO-S (RS3035-6) a three leg switching of three phase (3PH) solid state relay (SSR), suitable for loads up to 600Vac and a maximum current rating of 35 amps.
Simplicity coupled with great functionaility, real benefits include:
+ Cost Effective, so the budget doesn't compromise performance.
+ Precision Power Control, with fast and complex firing types.
+ Space Saving Design, making panel space no longer an issue.
+ Clean Electricity, as no interference is produced when switching at zero volts.
+ Lower Maintenance Costs, with increased heater element lifespan.
+ Built to Last, with an expected lifespan of over 10 years.

- Thyristors suitable for resistive and medium or long wave infrared loads
- Current range - 30A, 35A, 40A, 60A, 90A, 120A, 150A, 180A, 210A, 300A, 350A, 400A, 450A, 500A
- Supply voltage up to 480V or 600V AC as option
- Fully isolated from the power
- Zero crossing firing mode (ZC) or Burst Firing (4, 8 or 16 cycles selectable)
- Logic input signal 4 to 30V DC typical (SSR) plus 4-20mA or 0-10V DC Linear input as an option
- Constant current drain, independent of supply voltage with SSR input
- Heater Break (HB) alarm to diagnose partial or total load failure with automatic setting, relay alarm output and front LED indication. Available as an option
- Side by side mounting
- Special design Heatsink with high dissipation value
- IP20 protection
- Complies with CE and cUL specification
- Can be used in conjunction with REVO-PC to provide multi-zone control
Product Name | Solid State Relay - REVO-S 3PH 600V-35A |
---|---|
Software | No |
Firing Range | Zero Cross (SC), Burst Firing (BF) |
Input Signal | DC logic (SSR), 4-20mA, 0-10Vdc |
Communication | None |
Feedback Type | Open loop |
Option | Heater Break Alarm |
Ideal For | Normal Resistance, Medium & Long Wave Infrared load types |
Approvals | cUL and CE + EMC approved |
Altitude | Over 1000m of altitude reduce the nominal current of 2% for each 100m. |
Auxiliary Voltage Supply | 12:24Vac/dc (30A to 210A only with DC Linear input or HBA), otherwise available as follows: 90:130Vac 8VA Max |
Controlled Phases | 3 |
Heater Break Alarm | To diagnose partial or total load failure with automatic setup, relay alarm output and LED indication, available as an option |
Humidity | From 5 to 95% but without condensation or surface ice |
Mounting | Screw mounting |
Load Type | 3 Phase (4 wire - with neutral) |
Panel Sealing | IP20 |
Storage Temperature | -25 °C to 50 °C Max |
Voltage Power Supply | From 24V to 600Vac (690V available as option on specific models) |
Voltage Frequency | Automatically from 47 to 70 Hz |